HSS 20X12X3-4 - Section Properties

The HSS 20X12X3-4 is a steel section with a mass of 224.3 kg/m, an overall depth of 508 mm and width of 304.8 mm and a wall thickness of 17.7 mm. It has a cross-sectional area of 267.7 cm², a second moment of area Iᵧ of 91155 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4424.5 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
150.75 lb/ft (224.3 kg/m)
Depth
20 in (508 mm)
Width
12 in (304.8 mm)
Wall thickness
0.698 in (17.7 mm)
Area
41.5 in² (267.7 cm²)
Ask about capacity, buckling or detailing for HSS 20X12X3-4.
🔍 Open the full Steel Catalogue
or pick a unit on any row
HSS section profile showing the dimension symbols used for HSS 20X12X3-4

Dimension symbols for HSS sections. Not to scale.

HSS 20X12X3-4 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh20
508 mm
Width of sectionb12
304.8 mm
Web thicknesstw0.698
17.7 mm
Wall thicknesst0.698
17.7 mm

Mass and area

Mass per metremass150.75
224.3 kg/m
Cross-sectional areaA41.5
267.7 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2190
91155 cm⁴
Elastic section modulus about y-axisWel,y219
3588.8 cm³
Plastic section modulus about y-axisWpl,y270
4424.5 cm³
Radius of gyration about y-axisiy7.26
18.44 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz988
41124 cm⁴
Elastic section modulus about z-axisWel,z165
2703.9 cm³
Plastic section modulus about z-axisWpl,z190
3113.5 cm³
Radius of gyration about z-axisiz4.88
12.4 cm

Torsion and warping

Torsion constant (St Venant)It2220
92403 cm⁴

Is HSS 20X12X3-4 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
468.8 / 1526.5 kNm
Shear6%
187.5 / 3332.6 kN
Deflection61%
17.0 / 27.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HSS 20X12X3-4

HSS 20X12X3-4 has a mass of 150.75 lb/ft (224.3 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 2692 kg, which is the figure to use for a steel take-off or when checking a lift.

HSS 20X12X3-4 has a depth of 20 in (508 mm), a width of 12 in (304.8 mm), a web thickness of 0.698 in (17.7 mm), a wall thickness of 0.698 in (17.7 mm), with a cross-sectional area of 41.5 in² (267.7 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,424.5 cm³, and the elastic modulus Wel,y is 3,588.8 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1571 kNm before any stability check.

The second moment of area about the major axis, Iy, is 91,155 cm⁴, and about the minor axis Iz is 41,124 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 18.44 cm about the major axis and iz is 12.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 12.4 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 92,403 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related HSS sizes

HSS 20X16X5-16HSS 20X16X1-4HSS 20X12X1HSS 20X12X7-8HSS 20X12X5-8HSS 20X12X1-2HSS 20X12X3-8HSS 20X12X5-16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All HSS sizes
AISC HSS (Hollow Structural Sections)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…