CivilAxisCivilAxis
☕ Support🌐 Community

L 8X6X1-2 - Section Properties

The L 8X6X1-2 is a steel section with a mass of 34.2 kg/m, an overall depth of 152.4 mm. It has a cross-sectional area of 43.9 cm², a second moment of area Iᵧ of 1848 cm⁴, a plastic modulus Wₚₗ,ᵧ of 239.25 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
23 lb/ft (34.2 kg/m)
Depth
6 in (152.4 mm)
Area
6.8 in² (43.9 cm²)
Ask about capacity, buckling or detailing for L 8X6X1-2.
🔍 Open the full Steel Catalogue
or pick a unit on any row
L section profile showing the dimension symbols used for L 8X6X1-2

Dimension symbols for L sections. Not to scale.

L 8X6X1-2 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh6
152.4 mm

Mass and area

Mass per metremass23
34.2 kg/m
Cross-sectional areaA6.8
43.9 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy44.4
1848 cm⁴
Elastic section modulus about y-axisWel,y8.01
131.26 cm³
Plastic section modulus about y-axisWpl,y14.6
239.25 cm³
Radius of gyration about y-axisiy2.55
6.48 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz21.7
903.2 cm⁴
Elastic section modulus about z-axisWel,z4.79
78.494 cm³
Plastic section modulus about z-axisWpl,z8.52
139.62 cm³
Radius of gyration about z-axisiz1.79
4.55 cm

Torsion and warping

Torsion constant (St Venant)It0.584
24.31 cm⁴

Common questions about L 8X6X1-2

L 8X6X1-2 has a mass of 23 lb/ft (34.2 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 410 kg, which is the figure to use for a steel take-off or when checking a lift.

L 8X6X1-2 has a depth of 6 in (152.4 mm), with a cross-sectional area of 6.8 in² (43.9 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 239.25 cm³, and the elastic modulus Wel,y is 131.26 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 85 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,848 cm⁴, and about the minor axis Iz is 903.2 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 6.48 cm about the major axis and iz is 4.55 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.55 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 24.31 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related L sizes

L 8X6X7-8L 8X6X3-4L 8X6X5-8L 8X6X9-16L 8X6X7-16L 8X4X1L 8X4X7-8L 8X4X3-4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All L sizes
AISC L-Shapes (Angles)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…