CivilAxisCivilAxis
☕ Support🌐 Community

S 5X10 - Section Properties

The S 5X10 is a steel section with a mass of 14.9 kg/m, an overall depth of 127 mm and width of 76.2 mm. It has a cross-sectional area of 18.9 cm², a second moment of area Iᵧ of 512 cm⁴, a plastic modulus Wₚₗ,ᵧ of 92.751 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
10 lb/ft (14.9 kg/m)
Depth
5 in (127 mm)
Width
3 in (76.2 mm)
Area
2.93 in² (18.9 cm²)
Ask about capacity, buckling or detailing for S 5X10.
🔍 Open the full Steel Catalogue
or pick a unit on any row
S section profile showing the dimension symbols used for S 5X10

Dimension symbols for S sections. Not to scale.

S 5X10 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh5
127 mm
Width of sectionb3
76.2 mm
Web thicknesstw0.214
5.4 mm
Flange thicknesstf0.326
8.3 mm

Mass and area

Mass per metremass10
14.9 kg/m
Cross-sectional areaA2.93
18.9 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy12.3
512 cm⁴
Elastic section modulus about y-axisWel,y4.9
80.297 cm³
Plastic section modulus about y-axisWpl,y5.66
92.751 cm³
Radius of gyration about y-axisiy2.05
5.21 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1.19
49.53 cm⁴
Elastic section modulus about z-axisWel,z0.795
13.028 cm³
Plastic section modulus about z-axisWpl,z1.37
22.45 cm³
Radius of gyration about z-axisiz0.638
1.62 cm

Torsion and warping

Torsion constant (St Venant)It0.114
4.75 cm⁴

Is S 5X10 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
10.5 / 32.9 kNm
Shear12%
16.9 / 137.3 kN
Deflection61%
4.3 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about S 5X10

S 5X10 has a mass of 10 lb/ft (14.9 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 179 kg, which is the figure to use for a steel take-off or when checking a lift.

S 5X10 has a depth of 5 in (127 mm), a width of 3 in (76.2 mm), a web thickness of 0.214 in (5.4 mm), a flange thickness of 0.326 in (8.3 mm), with a cross-sectional area of 2.93 in² (18.9 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 92.751 cm³, and the elastic modulus Wel,y is 80.297 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 33 kNm before any stability check.

The second moment of area about the major axis, Iy, is 512 cm⁴, and about the minor axis Iz is 49.53 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5.21 cm about the major axis and iz is 1.62 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.62 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4.75 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related S sizes

S 8X23S 8X18.4S 6X17.25S 6X12.5S 4X9.5S 4X7.7S 3X7.5S 3X5.7

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All S sizes
AISC S-Shapes (American Standard Beam)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…