W 24X104 - Section Properties

The W 24X104 is a steel section with a mass of 154.8 kg/m, an overall depth of 612.1 mm and width of 325.1 mm. It has a cross-sectional area of 198.1 cm², a second moment of area Iᵧ of 129032 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4735.9 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
104 lb/ft (154.8 kg/m)
Depth
24.1 in (612.1 mm)
Width
12.8 in (325.1 mm)
Area
30.7 in² (198.1 cm²)
Ask about capacity, buckling or detailing for W 24X104.
🔍 Open the full Steel Catalogue
or pick a unit on any row
W section profile showing the dimension symbols used for W 24X104

Dimension symbols for W sections. Not to scale.

W 24X104 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh24.1
612.1 mm
Width of sectionb12.8
325.1 mm
Web thicknesstw0.5
12.7 mm
Flange thicknesstf0.75
19 mm

Mass and area

Mass per metremass104
154.8 kg/m
Cross-sectional areaA30.7
198.1 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3100
129032 cm⁴
Elastic section modulus about y-axisWel,y258
4227.9 cm³
Plastic section modulus about y-axisWpl,y289
4735.9 cm³
Radius of gyration about y-axisiy10.1
25.65 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz259
10780 cm⁴
Elastic section modulus about z-axisWel,z40.7
666.95 cm³
Plastic section modulus about z-axisWpl,z62.4
1022.6 cm³
Radius of gyration about z-axisiz2.91
7.39 cm

Torsion and warping

Torsion constant (St Venant)It4.72
196.5 cm⁴
Warping constantIw35200
9.45 dm⁶

Is W 24X104 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending36%
540.0 / 1500.9 kNm
Shear11%
180.0 / 1577.7 kN
Deflection60%
19.9 / 33.3 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about W 24X104

W 24X104 has a mass of 104 lb/ft (154.8 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 1858 kg, which is the figure to use for a steel take-off or when checking a lift.

W 24X104 has a depth of 24.1 in (612.1 mm), a width of 12.8 in (325.1 mm), a web thickness of 0.5 in (12.7 mm), a flange thickness of 0.75 in (19 mm), with a cross-sectional area of 30.7 in² (198.1 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,735.9 cm³, and the elastic modulus Wel,y is 4,227.9 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1681 kNm before any stability check.

The second moment of area about the major axis, Iy, is 129,032 cm⁴, and about the minor axis Iz is 10,780 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 25.65 cm about the major axis and iz is 7.39 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.39 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 196.5 cm⁴, and the warping constant Iw is 9.45 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related W sizes

W 24X162W 24X146W 24X131W 24X117W 24X103W 24X94W 24X84W 24X76

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 600vs UB 610×305×149vs S 24X106

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All W sizes
AISC W-Shapes (Wide-Flange)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…