CivilAxisCivilAxis
☕ Support🌐 Community

CHS 323.9×12.5 - Section Properties

The CHS 323.9×12.5 is a steel section with a mass of 95.99 kg/m, an overall depth of 323.9 mm and width of 323.9 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 122 cm², a second moment of area Iᵧ of 14850 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1213 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
95.99 kg/m
Depth
323.9 mm
Width
323.9 mm
Wall thickness
12.5 mm
Area
122 cm²
Ask about capacity, buckling or detailing for CHS 323.9×12.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CHS 323.9×12.5

Dimension symbols for CHS Cold-formed sections. Not to scale.

CHS 323.9×12.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh323.9
Width of sectionb323.9
Wall thicknesst12.5

Mass and area

Mass per metremass95.99
Cross-sectional areaA122

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy14850
Elastic section modulus about y-axisWel,y917
Plastic section modulus about y-axisWpl,y1213
Radius of gyration about y-axisiy11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz14850
Elastic section modulus about z-axisWel,z917
Plastic section modulus about z-axisWpl,z1213
Radius of gyration about z-axisiz11

Torsion and warping

Torsion constant (St Venant)It29690
Section modulus for torsionWt1833

Surface area

Surface area per metreSA/m1.02

Is CHS 323.9×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending28%
118.8 / 430.6 kNm
Shear6%
73.1 / 1250.3 kN
Deflection62%
11.2 / 18.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 323.9×12.5

CHS 323.9×12.5 has a mass of 95.99 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1152 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 323.9×12.5 has a depth of 323.9 mm, a width of 323.9 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 122 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,213 cm³, and the elastic modulus Wel,y is 917 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 431 kNm before any stability check.

The second moment of area about the major axis, Iy, is 14,850 cm⁴, and about the minor axis Iz is 14,850 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11 cm about the major axis and iz is 11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 11 cm a 1.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 29,690 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CHS 323.9×6.3CHS 323.9×8CHS 323.9×10CHS 323.9×12CHS 323.9×16CHS 355.6×5CHS 355.6×6CHS 355.6×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section