CivilAxisCivilAxis
☕ Support🌐 Community

CHS 508×6.3 - Section Properties

The CHS 508×6.3 is a steel section with a mass of 77.95 kg/m, an overall depth of 508 mm and width of 508 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 99.3 cm², a second moment of area Iᵧ of 31250 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1586 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
77.95 kg/m
Depth
508 mm
Width
508 mm
Wall thickness
6.3 mm
Area
99.3 cm²
Ask about capacity, buckling or detailing for CHS 508×6.3.
🔍 Open the full Steel Catalogue
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CHS 508×6.3

Dimension symbols for CHS Cold-formed sections. Not to scale.

CHS 508×6.3 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh508
Width of sectionb508
Wall thicknesst6.3

Mass and area

Mass per metremass77.95
Cross-sectional areaA99.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy31250
Elastic section modulus about y-axisWel,y1230
Plastic section modulus about y-axisWpl,y1586
Radius of gyration about y-axisiy17.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz31250
Elastic section modulus about z-axisWel,z1230
Plastic section modulus about z-axisWpl,z1586
Radius of gyration about z-axisiz17.7

Torsion and warping

Torsion constant (St Venant)It62490
Section modulus for torsionWt2460

Surface area

Surface area per metreSA/m1.6

Common questions about CHS 508×6.3

CHS 508×6.3 has a mass of 77.95 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 935 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 508×6.3 has a depth of 508 mm, a width of 508 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 99.3 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,586 cm³, and the elastic modulus Wel,y is 1,230 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 563 kNm before any stability check.

The second moment of area about the major axis, Iy, is 31,250 cm⁴, and about the minor axis Iz is 31,250 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 17.7 cm about the major axis and iz is 17.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 17.7 cm a 1.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 62,490 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CHS 457×12CHS 457×12.5CHS 457×16CHS 508×6CHS 508×8CHS 508×10CHS 508×12CHS 508×12.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Cold-formed sizes
Circular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…