CivilAxisCivilAxis
☕ Support🌐 Community

CHS 177.8×5 - Section Properties

The CHS 177.8×5 is a steel section with a mass of 21.31 kg/m, an overall depth of 177.8 mm and width of 177.8 mm and a wall thickness of 5 mm. It has a cross-sectional area of 27.1 cm², a second moment of area Iᵧ of 1014 cm⁴, a plastic modulus Wₚₗ,ᵧ of 149 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
21.31 kg/m
Depth
177.8 mm
Width
177.8 mm
Wall thickness
5 mm
Area
27.1 cm²
Ask about capacity, buckling or detailing for CHS 177.8×5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
CHS section profile showing the dimension symbols used for CHS 177.8×5

Dimension symbols for CHS sections. Not to scale.

CHS 177.8×5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh177.8
Width of sectionb177.8
Wall thicknesst5

Mass and area

Mass per metremass21.31
Cross-sectional areaA27.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1014
Elastic section modulus about y-axisWel,y114
Plastic section modulus about y-axisWpl,y149
Radius of gyration about y-axisiy6.11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1014
Elastic section modulus about z-axisWel,z114
Plastic section modulus about z-axisWpl,z149
Radius of gyration about z-axisiz6.11

Torsion and warping

Torsion constant (St Venant)It2028
Section modulus for torsionWt228

Surface area

Surface area per metreSA/m0.559

Is CHS 177.8×5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending28%
14.9 / 52.9 kNm
Shear6%
17.1 / 277.7 kN
Deflection61%
6.0 / 9.7 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 177.8×5

CHS 177.8×5 has a mass of 21.31 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 256 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 177.8×5 has a depth of 177.8 mm, a width of 177.8 mm, a wall thickness of 5 mm, with a cross-sectional area of 27.1 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 149 cm³, and the elastic modulus Wel,y is 114 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 53 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,014 cm⁴, and about the minor axis Iz is 1,014 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 6.11 cm about the major axis and iz is 6.11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.11 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 2,028 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS sizes

CHS 168.3×12CHS 168.3×12.5CHS 168.3×14CHS 177.8×4.5CHS 177.8×6.3CHS 177.8×8CHS 177.8×10CHS 177.8×12

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CHS 168.3×5.6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS sizes
Circular Hollow Sections (CHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.