CHS 273×12 - Section Properties

The CHS 273×12 is a steel section with a mass of 77.24 kg/m, an overall depth of 273 mm and width of 273 mm and a wall thickness of 12 mm. It has a cross-sectional area of 98.4 cm², a second moment of area Iᵧ of 8396 cm⁴, a plastic modulus Wₚₗ,ᵧ of 818 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
77.24 kg/m
Depth
273 mm
Width
273 mm
Wall thickness
12 mm
Area
98.4 cm²
Ask about capacity, buckling or detailing for CHS 273×12.
🔍 Open the full Steel Catalogue
or pick a unit on any row
CHS section profile showing the dimension symbols used for CHS 273×12

Dimension symbols for CHS sections. Not to scale.

CHS 273×12 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh273
Width of sectionb273
Wall thicknesst12

Mass and area

Mass per metremass77.24
Cross-sectional areaA98.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy8396
Elastic section modulus about y-axisWel,y615
Plastic section modulus about y-axisWpl,y818
Radius of gyration about y-axisiy9.24

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz8396
Elastic section modulus about z-axisWel,z615
Plastic section modulus about z-axisWpl,z818
Radius of gyration about z-axisiz9.24

Torsion and warping

Torsion constant (St Venant)It16790
Section modulus for torsionWt1230

Surface area

Surface area per metreSA/m0.858

Is CHS 273×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending27%
79.4 / 290.4 kNm
Shear6%
57.8 / 1008.4 kN
Deflection62%
9.5 / 15.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 273×12

CHS 273×12 has a mass of 77.24 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 927 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 273×12 has a depth of 273 mm, a width of 273 mm, a wall thickness of 12 mm, with a cross-sectional area of 98.4 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 818 cm³, and the elastic modulus Wel,y is 615 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 290 kNm before any stability check.

The second moment of area about the major axis, Iy, is 8,396 cm⁴, and about the minor axis Iz is 8,396 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.24 cm about the major axis and iz is 9.24 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.24 cm a 0.9 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 16,790 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS sizes

CHS 273×6CHS 273×6.3CHS 273×8CHS 273×10CHS 273×12.5CHS 273×14CHS 273×14.2CHS 273×16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS sizes
Circular Hollow Sections (CHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…