CivilAxisCivilAxis
☕ Support🌐 Community

CHS 508×25 - Section Properties

The CHS 508×25 is a steel section with a mass of 297.79 kg/m, an overall depth of 508 mm and width of 508 mm and a wall thickness of 25 mm. It has a cross-sectional area of 379 cm², a second moment of area Iᵧ of 110900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5837 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
297.79 kg/m
Depth
508 mm
Width
508 mm
Wall thickness
25 mm
Area
379 cm²
Ask about capacity, buckling or detailing for CHS 508×25.
🔍 Open the full Steel Catalogue
or pick a unit on any row
CHS section profile showing the dimension symbols used for CHS 508×25

Dimension symbols for CHS sections. Not to scale.

CHS 508×25 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh508
Width of sectionb508
Wall thicknesst25

Mass and area

Mass per metremass297.79
Cross-sectional areaA379

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy110900
Elastic section modulus about y-axisWel,y4367
Plastic section modulus about y-axisWpl,y5837
Radius of gyration about y-axisiy17.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz110900
Elastic section modulus about z-axisWel,z4367
Plastic section modulus about z-axisWpl,z5837
Radius of gyration about z-axisiz17.1

Torsion and warping

Torsion constant (St Venant)It221800
Section modulus for torsionWt8734

Surface area

Surface area per metreSA/m1.6

Is CHS 508×25 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending28%
562.5 / 2013.8 kNm
Shear6%
225.0 / 3774.6 kN
Deflection60%
16.8 / 27.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CHS 508×25

CHS 508×25 has a mass of 297.79 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 3573 kg, which is the figure to use for a steel take-off or when checking a lift.

CHS 508×25 has a depth of 508 mm, a width of 508 mm, a wall thickness of 25 mm, with a cross-sectional area of 379 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,837 cm³, and the elastic modulus Wel,y is 4,367 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2072 kNm before any stability check.

The second moment of area about the major axis, Iy, is 110,900 cm⁴, and about the minor axis Iz is 110,900 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 17.1 cm about the major axis and iz is 17.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 17.1 cm a 1.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 221,800 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS sizes

CHS 508×12CHS 508×12.5CHS 508×14.2CHS 508×16CHS 508×20CHS 508×32CHS 508×40CHS 508×50

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS sizes
Circular Hollow Sections (CHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…