CivilAxisCivilAxis
☕ Support🌐 Community

PFC 230×90 - Section Properties

The PFC 230×90 is a steel section with a mass of 32.2 kg/m, an overall depth of 230 mm and width of 90 mm. It has a cross-sectional area of 41 cm², a second moment of area Iᵧ of 3518 cm⁴, a plastic modulus Wₚₗ,ᵧ of 355 cm³, tabulated by CivilAxis from Continental Steel.

Mass
32.2 kg/m
Depth
230 mm
Width
90 mm
Area
41 cm²
Ask about capacity, buckling or detailing for PFC 230×90.
🔍 Open the full Steel Catalogue
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 230×90

Dimension symbols for PFC sections. Not to scale.

PFC 230×90 section properties to Continental Steel.

Geometry

Depth of sectionh230
Width of sectionb90
Web thicknesstw7.5
Flange thicknesstf14
Root fillet radiusr12
Depth between filletsd178

Mass and area

Mass per metremass32.2
Cross-sectional areaA41

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3518
Elastic section modulus about y-axisWel,y306
Plastic section modulus about y-axisWpl,y355
Radius of gyration about y-axisiy9.27

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz334
Elastic section modulus about z-axisWel,z55
Plastic section modulus about z-axisWpl,z98.9
Radius of gyration about z-axisiz2.86

Torsion and warping

Torsion constant (St Venant)It19.3
Warping constantIw0.028

Classification and stability

Flange local-buckling ratiocf/tf6.43
Web local-buckling ratiocw/tw23.7
Buckling parameteru0.95
Torsional indexX15.1

Detailing dimensions

Centroid distance from back of leg (y)cy2.92

Is PFC 230×90 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending30%
38.0 / 126.0 kNm
Shear9%
33.8 / 379.8 kN
Deflection58%
7.2 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 230×90

PFC 230×90 has a mass of 32.2 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 386 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 230×90 has a depth of 230 mm, a width of 90 mm, a web thickness of 7.5 mm, a flange thickness of 14 mm, with a cross-sectional area of 41 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 355 cm³, and the elastic modulus Wel,y is 306 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 126 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,518 cm⁴, and about the minor axis Iz is 334 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.43 for the flange and cw/tw = 23.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.27 cm about the major axis and iz is 2.86 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.86 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 19.3 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 180×90PFC 200×75PFC 200×90PFC 230×75PFC 250×90PFC 260×75PFC 260×90PFC 300×90

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 230×90×32

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…