CivilAxisCivilAxis
☕ Support🌐 Community

PFC 260×90 - Section Properties

The PFC 260×90 is a steel section with a mass of 34.8 kg/m, an overall depth of 260 mm and width of 90 mm. It has a cross-sectional area of 44.4 cm², a second moment of area Iᵧ of 4728 cm⁴, a plastic modulus Wₚₗ,ᵧ of 425 cm³, tabulated by CivilAxis from Continental Steel.

Mass
34.8 kg/m
Depth
260 mm
Width
90 mm
Area
44.4 cm²
Ask about capacity, buckling or detailing for PFC 260×90.
🔍 Open the full Steel Catalogue
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 260×90

Dimension symbols for PFC sections. Not to scale.

PFC 260×90 section properties to Continental Steel.

Geometry

Depth of sectionh260
Width of sectionb90
Web thicknesstw8
Flange thicknesstf14
Root fillet radiusr12
Depth between filletsd208

Mass and area

Mass per metremass34.8
Cross-sectional areaA44.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4728
Elastic section modulus about y-axisWel,y364
Plastic section modulus about y-axisWpl,y425
Radius of gyration about y-axisiy10.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz353
Elastic section modulus about z-axisWel,z56.3
Plastic section modulus about z-axisWpl,z102
Radius of gyration about z-axisiz2.82

Torsion and warping

Torsion constant (St Venant)It20.6
Warping constantIw0.038

Classification and stability

Flange local-buckling ratiocf/tf6.43
Web local-buckling ratiocw/tw26
Buckling parameteru0.942
Torsional indexX17.2

Detailing dimensions

Centroid distance from back of leg (y)cy2.74

Is PFC 260×90 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
46.9 / 150.9 kNm
Shear8%
37.5 / 450.9 kN
Deflection59%
8.2 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 260×90

PFC 260×90 has a mass of 34.8 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 418 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 260×90 has a depth of 260 mm, a width of 90 mm, a web thickness of 8 mm, a flange thickness of 14 mm, with a cross-sectional area of 44.4 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 425 cm³, and the elastic modulus Wel,y is 364 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 151 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,728 cm⁴, and about the minor axis Iz is 353 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.43 for the flange and cw/tw = 26 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.3 cm about the major axis and iz is 2.82 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.82 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 20.6 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 230×75PFC 230×90PFC 250×90PFC 260×75PFC 300×90PFC 300×100PFC 380×100PFC 430×100

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 260×90×35vs C 10X30

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…