RHS 120×60×6 - Section Properties
The RHS 120×60×6 is a steel section with a mass of 15.1 kg/m, an overall depth of 120 mm and width of 60 mm and a wall thickness of 6 mm. It has a cross-sectional area of 19.2 cm², a second moment of area Iᵧ of 328 cm⁴, a plastic modulus Wₚₗ,ᵧ of 70.6 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 120×60×6.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 120×60×6 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 58% utilised, deflection governs
Bending26%
6.4 / 25.1 kNmShear4%
10.3 / 262.3 kNDeflection58%
4.1 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 120×60×6
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.