RHS 200×100×4.5 - Section Properties

The RHS 200×100×4.5 is a steel section with a mass of 20.5 kg/m, an overall depth of 200 mm and width of 100 mm and a wall thickness of 4.5 mm. It has a cross-sectional area of 25.7 cm², a second moment of area Iᵧ of 1331 cm⁴, a plastic modulus Wₚₗ,ᵧ of 165 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
20.5 kg/m
Depth
200 mm
Width
100 mm
Wall thickness
4.5 mm
Area
25.7 cm²
Ask about capacity, buckling or detailing for RHS 200×100×4.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for RHS 200×100×4.5

Dimension symbols for RHS Cold-formed sections. Not to scale.

RHS 200×100×4.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh200
Width of sectionb100
Wall thicknesst4.5

Mass and area

Mass per metremass20.5
Cross-sectional areaA25.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1331
Elastic section modulus about y-axisWel,y133
Plastic section modulus about y-axisWpl,y165
Radius of gyration about y-axisiy7.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz455
Elastic section modulus about z-axisWel,z90.9
Plastic section modulus about z-axisWpl,z102
Radius of gyration about z-axisiz4.21

Torsion and warping

Torsion constant (St Venant)It1097
Section modulus for torsionWt157

Surface area

Surface area per metreSA/m0.585

Is RHS 200×100×4.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending28%
16.5 / 58.6 kNm
Shear5%
16.5 / 351.2 kN
Deflection59%
6.6 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 200×100×4.5

RHS 200×100×4.5 has a mass of 20.5 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 246 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 200×100×4.5 has a depth of 200 mm, a width of 100 mm, a wall thickness of 4.5 mm, with a cross-sectional area of 25.7 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 165 cm³, and the elastic modulus Wel,y is 133 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 59 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,331 cm⁴, and about the minor axis Iz is 455 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.2 cm about the major axis and iz is 4.21 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.21 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,097 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

RHS 175×125×6.4RHS 175×125×9.5RHS 175×125×12.7RHS 200×100×4RHS 200×100×4.6RHS 200×100×4.8RHS 200×100×5RHS 200×100×6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…