CivilAxisCivilAxis
☕ Support🌐 Community

RHS 200×150×12.7 - Section Properties

The RHS 200×150×12.7 is a steel section with a mass of 62.5 kg/m, an overall depth of 200 mm and width of 150 mm and a wall thickness of 12.7 mm. It has a cross-sectional area of 75.5 cm², a second moment of area Iᵧ of 3794 cm⁴, a plastic modulus Wₚₗ,ᵧ of 482 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
62.5 kg/m
Depth
200 mm
Width
150 mm
Wall thickness
12.7 mm
Area
75.5 cm²
Ask about capacity, buckling or detailing for RHS 200×150×12.7.
🔍 Open the full Steel Catalogue
or pick a unit on any row
RHS Cold-formed section profile showing the dimension symbols used for RHS 200×150×12.7

Dimension symbols for RHS Cold-formed sections. Not to scale.

RHS 200×150×12.7 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh200
Width of sectionb150
Wall thicknesst12.7

Mass and area

Mass per metremass62.5
Cross-sectional areaA75.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3794
Elastic section modulus about y-axisWel,y379
Plastic section modulus about y-axisWpl,y482
Radius of gyration about y-axisiy7.09

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2432
Elastic section modulus about z-axisWel,z324
Plastic section modulus about z-axisWpl,z396
Radius of gyration about z-axisiz5.67

Torsion and warping

Torsion constant (St Venant)It5316
Section modulus for torsionWt552

Surface area

Surface area per metreSA/m0.635

Is RHS 200×150×12.7 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending28%
48.0 / 171.1 kNm
Shear5%
48.0 / 884.3 kN
Deflection60%
6.7 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 200×150×12.7

RHS 200×150×12.7 has a mass of 62.5 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 750 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 200×150×12.7 has a depth of 200 mm, a width of 150 mm, a wall thickness of 12.7 mm, with a cross-sectional area of 75.5 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 482 cm³, and the elastic modulus Wel,y is 379 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 171 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,794 cm⁴, and about the minor axis Iz is 2,432 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.09 cm about the major axis and iz is 5.67 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.67 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5,316 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Cold-formed sizes

RHS 200×150×6.3RHS 200×150×9RHS 200×150×9.5RHS 200×150×12RHS 250×150×5RHS 250×150×6RHS 250×150×6.3RHS 250×150×8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs RHS 200×100×16vs RHS 200×120×14.2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Cold-formed sizes
Rectangular Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.