RHS 60×40×4.5 - Section Properties
The RHS 60×40×4.5 is a steel section with a mass of 6.01 kg/m, an overall depth of 60 mm and width of 40 mm and a wall thickness of 4.5 mm. It has a cross-sectional area of 7.67 cm², a second moment of area Iᵧ of 33.3 cm⁴, a plastic modulus Wₚₗ,ᵧ of 14.3 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 60×40×4.5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 60×40×4.5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending33%
1.7 / 5.1 kNmShear7%
6.8 / 94.3 kNDeflection60%
1.7 / 2.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.