RHS 90×50×5 - Section Properties
The RHS 90×50×5 is a steel section with a mass of 9.7 kg/m, an overall depth of 90 mm and width of 50 mm and a wall thickness of 5 mm. It has a cross-sectional area of 12.4 cm², a second moment of area Iᵧ of 121 cm⁴, a plastic modulus Wₚₗ,ᵧ of 34.4 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for RHS 90×50×5.
or pick a unit on any row

Dimension symbols for RHS Cold-formed sections. Not to scale.
Is RHS 90×50×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending25%
3.0 / 12.2 kNmShear4%
6.0 / 163.4 kNDeflection59%
3.3 / 5.6 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about RHS 90×50×5
Related RHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…