SHS 100×100×9 - Section Properties

The SHS 100×100×9 is a steel section with a mass of 24.1 kg/m, an overall depth of 100 mm and width of 100 mm and a wall thickness of 9 mm. It has a cross-sectional area of 30 cm², a second moment of area Iᵧ of 391 cm⁴, a plastic modulus Wₚₗ,ᵧ of 98.6 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
24.1 kg/m
Depth
100 mm
Width
100 mm
Wall thickness
9 mm
Area
30 cm²
Ask about capacity, buckling or detailing for SHS 100×100×9.
🔍 Open the full Steel Catalogue →
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 100×100×9

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 100×100×9 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh100
Width of sectionb100
Wall thicknesst9

Mass and area

Mass per metremass24.1
Cross-sectional areaA30

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy391
Elastic section modulus about y-axisWel,y78.1
Plastic section modulus about y-axisWpl,y98.6
Radius of gyration about y-axisiy3.61

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz391
Elastic section modulus about z-axisWel,z78.1
Plastic section modulus about z-axisWpl,z98.6
Radius of gyration about z-axisiz3.61

Torsion and warping

Torsion constant (St Venant)It700
Section modulus for torsionWt123

Surface area

Surface area per metreSA/m0.361

Is SHS 100×100×9 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

✅Passes - 59% utilised, deflection governs
Bending28%
9.8 / 35.0 kNm
Shear6%
19.5 / 307.4 kN
Deflection59%
3.3 / 5.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 100×100×9

SHS 100×100×9 has a mass of 24.1 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 289 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 100×100×9 has a depth of 100 mm, a width of 100 mm, a wall thickness of 9 mm, with a cross-sectional area of 30 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 98.6 cm³, and the elastic modulus Wel,y is 78.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 35 kNm before any stability check.

The second moment of area about the major axis, Iy, is 391 cm⁴, and about the minor axis Iz is 391 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 3.61 cm about the major axis and iz is 3.61 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.61 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 700 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 100×100×6SHS 100×100×6.3SHS 100×100×6.4SHS 100×100×8SHS 120×120×4SHS 120×120×5SHS 120×120×6SHS 120×120×6.3

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 100×100×8 →

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE) →📘 Section modulus explained: elastic (Wel) vs plastic (Wpl) →📘 SHS vs RHS vs CHS: choosing a hollow steel section →
All SHS Cold-formed sizes →
Square Hollow Sections - Cold-formed
Full steel section tables →
Every UB, UC, hollow, channel & angle section
Open the interactive tool →
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…