SHS 120×120×4 - Section Properties
The SHS 120×120×4 is a steel section with a mass of 14.2 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 4 mm. It has a cross-sectional area of 18.1 cm², a second moment of area Iᵧ of 402 cm⁴, a plastic modulus Wₚₗ,ᵧ of 78.3 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 120×120×4.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 120×120×4 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending30%
8.2 / 27.8 kNmShear7%
13.1 / 185.5 kNDeflection61%
4.2 / 6.9 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.