SHS 120×120×8 - Section Properties

The SHS 120×120×8 is a steel section with a mass of 26.4 kg/m, an overall depth of 120 mm and width of 120 mm and a wall thickness of 8 mm. It has a cross-sectional area of 33.6 cm², a second moment of area Iᵧ of 677 cm⁴, a plastic modulus Wₚₗ,ᵧ of 138 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
26.4 kg/m
Depth
120 mm
Width
120 mm
Wall thickness
8 mm
Area
33.6 cm²
Ask about capacity, buckling or detailing for SHS 120×120×8.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 120×120×8

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 120×120×8 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh120
Width of sectionb120
Wall thicknesst8

Mass and area

Mass per metremass26.4
Cross-sectional areaA33.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy677
Elastic section modulus about y-axisWel,y113
Plastic section modulus about y-axisWpl,y138
Radius of gyration about y-axisiy4.49

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz677
Elastic section modulus about z-axisWel,z113
Plastic section modulus about z-axisWpl,z138
Radius of gyration about z-axisiz4.49

Torsion and warping

Torsion constant (St Venant)It1163
Section modulus for torsionWt175

Surface area

Surface area per metreSA/m0.446

Is SHS 120×120×8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending29%
14.1 / 49.0 kNm
Shear7%
22.5 / 344.3 kN
Deflection62%
4.3 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 120×120×8

SHS 120×120×8 has a mass of 26.4 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 317 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 120×120×8 has a depth of 120 mm, a width of 120 mm, a wall thickness of 8 mm, with a cross-sectional area of 33.6 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 138 cm³, and the elastic modulus Wel,y is 113 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 49 kNm before any stability check.

The second moment of area about the major axis, Iy, is 677 cm⁴, and about the minor axis Iz is 677 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.49 cm about the major axis and iz is 4.49 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.49 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,163 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 120×120×4SHS 120×120×5SHS 120×120×6SHS 120×120×6.3SHS 125×125×2.3SHS 125×125×3SHS 125×125×3.2SHS 125×125×4.5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 120×120×7.1

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…