CivilAxisCivilAxis
☕ Support🌐 Community

SHS 125×125×3.2 - Section Properties

The SHS 125×125×3.2 is a steel section with a mass of 12 kg/m, an overall depth of 125 mm and width of 125 mm and a wall thickness of 3.2 mm. It has a cross-sectional area of 15.3 cm², a second moment of area Iᵧ of 376 cm⁴, a plastic modulus Wₚₗ,ᵧ of 69.6 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
12 kg/m
Depth
125 mm
Width
125 mm
Wall thickness
3.2 mm
Area
15.3 cm²
Ask about capacity, buckling or detailing for SHS 125×125×3.2.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 125×125×3.2

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 125×125×3.2 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh125
Width of sectionb125
Wall thicknesst3.2

Mass and area

Mass per metremass12
Cross-sectional areaA15.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy376
Elastic section modulus about y-axisWel,y60.1
Plastic section modulus about y-axisWpl,y69.6
Radius of gyration about y-axisiy4.95

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz376
Elastic section modulus about z-axisWel,z60.1
Plastic section modulus about z-axisWpl,z69.6
Radius of gyration about z-axisiz4.95

Torsion and warping

Torsion constant (St Venant)It587
Section modulus for torsionWt90.2

Surface area

Surface area per metreSA/m0.489

Common questions about SHS 125×125×3.2

SHS 125×125×3.2 has a mass of 12 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 144 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 125×125×3.2 has a depth of 125 mm, a width of 125 mm, a wall thickness of 3.2 mm, with a cross-sectional area of 15.3 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 69.6 cm³, and the elastic modulus Wel,y is 60.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 25 kNm before any stability check.

The second moment of area about the major axis, Iy, is 376 cm⁴, and about the minor axis Iz is 376 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.95 cm about the major axis and iz is 4.95 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.95 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 587 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 120×120×6.3SHS 120×120×8SHS 125×125×2.3SHS 125×125×3SHS 125×125×4.5SHS 125×125×4.6SHS 125×125×4.8SHS 125×125×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.