SHS 125×125×5 - Section Properties
The SHS 125×125×5 is a steel section with a mass of 18.7 kg/m, an overall depth of 125 mm and width of 125 mm and a wall thickness of 5 mm. It has a cross-sectional area of 23.4 cm², a second moment of area Iᵧ of 553 cm⁴, a plastic modulus Wₚₗ,ᵧ of 104 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 125×125×5.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 125×125×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
11.1 / 36.9 kNmShear7%
17.8 / 239.8 kNDeflection60%
4.2 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 125×125×5
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…