SHS 175×175×12.7 - Section Properties

The SHS 175×175×12.7 is a steel section with a mass of 62.5 kg/m, an overall depth of 175 mm and width of 175 mm and a wall thickness of 12.7 mm. It has a cross-sectional area of 75.5 cm², a second moment of area Iᵧ of 3124 cm⁴, a plastic modulus Wₚₗ,ᵧ of 443 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
62.5 kg/m
Depth
175 mm
Width
175 mm
Wall thickness
12.7 mm
Area
75.5 cm²
Ask about capacity, buckling or detailing for SHS 175×175×12.7.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 175×175×12.7

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 175×175×12.7 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh175
Width of sectionb175
Wall thicknesst12.7

Mass and area

Mass per metremass62.5
Cross-sectional areaA75.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3124
Elastic section modulus about y-axisWel,y357
Plastic section modulus about y-axisWpl,y443
Radius of gyration about y-axisiy6.43

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3124
Elastic section modulus about z-axisWel,z357
Plastic section modulus about z-axisWpl,z443
Radius of gyration about z-axisiz6.43

Torsion and warping

Torsion constant (St Venant)It5585
Section modulus for torsionWt568

Surface area

Surface area per metreSA/m0.635

Is SHS 175×175×12.7 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending29%
45.9 / 157.3 kNm
Shear7%
52.5 / 773.7 kN
Deflection61%
6.0 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 175×175×12.7

SHS 175×175×12.7 has a mass of 62.5 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 750 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 175×175×12.7 has a depth of 175 mm, a width of 175 mm, a wall thickness of 12.7 mm, with a cross-sectional area of 75.5 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 443 cm³, and the elastic modulus Wel,y is 357 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 157 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,124 cm⁴, and about the minor axis Iz is 3,124 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 6.43 cm about the major axis and iz is 6.43 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.43 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5,585 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 175×175×6SHS 175×175×6.4SHS 175×175×9SHS 175×175×9.5SHS 180×180×5SHS 180×180×6SHS 180×180×6.3SHS 180×180×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…