SHS 175×175×12.7 - Section Properties
The SHS 175×175×12.7 is a steel section with a mass of 62.5 kg/m, an overall depth of 175 mm and width of 175 mm and a wall thickness of 12.7 mm. It has a cross-sectional area of 75.5 cm², a second moment of area Iᵧ of 3124 cm⁴, a plastic modulus Wₚₗ,ᵧ of 443 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 175×175×12.7.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 175×175×12.7 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending29%
45.9 / 157.3 kNmShear7%
52.5 / 773.7 kNDeflection61%
6.0 / 9.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 175×175×12.7
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…