SHS 180×180×5 - Section Properties
The SHS 180×180×5 is a steel section with a mass of 27 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 5 mm. It has a cross-sectional area of 34.4 cm², a second moment of area Iᵧ of 1737 cm⁴, a plastic modulus Wₚₗ,ᵧ of 224 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 180×180×5.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is SHS 180×180×5 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending37%
25.3 / 68.5 kNmShear8%
28.9 / 352.5 kNDeflection61%
5.9 / 9.7 mmClass 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 180×180×5
Related SHS Cold-formed sizes
Learn more
Rate thisNo ratings yet