SHS 203×203×6.4 - Section Properties

The SHS 203×203×6.4 is a steel section with a mass of 38.4 kg/m, an overall depth of 203 mm and width of 203 mm and a wall thickness of 6.4 mm. It has a cross-sectional area of 48.9 cm², a second moment of area Iᵧ of 3103 cm⁴, a plastic modulus Wₚₗ,ᵧ of 357 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
38.4 kg/m
Depth
203 mm
Width
203 mm
Wall thickness
6.4 mm
Area
48.9 cm²
Ask about capacity, buckling or detailing for SHS 203×203×6.4.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 203×203×6.4

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 203×203×6.4 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh203
Width of sectionb203
Wall thicknesst6.4

Mass and area

Mass per metremass38.4
Cross-sectional areaA48.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3103
Elastic section modulus about y-axisWel,y306
Plastic section modulus about y-axisWpl,y357
Radius of gyration about y-axisiy7.96

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3103
Elastic section modulus about z-axisWel,z306
Plastic section modulus about z-axisWpl,z357
Radius of gyration about z-axisiz7.96

Torsion and warping

Torsion constant (St Venant)It4973
Section modulus for torsionWt464

Surface area

Surface area per metreSA/m0.785

Is SHS 203×203×6.4 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
39.0 / 126.7 kNm
Shear8%
39.0 / 501.1 kN
Deflection60%
6.6 / 11.1 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 203×203×6.4

SHS 203×203×6.4 has a mass of 38.4 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 461 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 203×203×6.4 has a depth of 203 mm, a width of 203 mm, a wall thickness of 6.4 mm, with a cross-sectional area of 48.9 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 357 cm³, and the elastic modulus Wel,y is 306 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 127 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,103 cm⁴, and about the minor axis Iz is 3,103 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.96 cm about the major axis and iz is 7.96 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.96 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4,973 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 200×200×10SHS 200×200×12SHS 200×200×12.5SHS 203×203×4.5SHS 203×203×9.5SHS 203×203×12.7SHS 250×250×6SHS 250×250×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section