CivilAxisCivilAxis
☕ Support🌐 Community

SHS 203×203×9.5 - Section Properties

The SHS 203×203×9.5 is a steel section with a mass of 56 kg/m, an overall depth of 203 mm and width of 203 mm and a wall thickness of 9.5 mm. It has a cross-sectional area of 70.4 cm², a second moment of area Iᵧ of 4288 cm⁴, a plastic modulus Wₚₗ,ᵧ of 503 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
56 kg/m
Depth
203 mm
Width
203 mm
Wall thickness
9.5 mm
Area
70.4 cm²
Ask about capacity, buckling or detailing for SHS 203×203×9.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 203×203×9.5

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 203×203×9.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh203
Width of sectionb203
Wall thicknesst9.5

Mass and area

Mass per metremass56
Cross-sectional areaA70.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4288
Elastic section modulus about y-axisWel,y422
Plastic section modulus about y-axisWpl,y503
Radius of gyration about y-axisiy7.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4288
Elastic section modulus about z-axisWel,z422
Plastic section modulus about z-axisWpl,z503
Radius of gyration about z-axisiz7.8

Torsion and warping

Torsion constant (St Venant)It7088
Section modulus for torsionWt646

Surface area

Surface area per metreSA/m0.771

Is SHS 203×203×9.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
54.0 / 178.6 kNm
Shear7%
54.0 / 721.5 kN
Deflection60%
6.7 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 203×203×9.5

SHS 203×203×9.5 has a mass of 56 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 672 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 203×203×9.5 has a depth of 203 mm, a width of 203 mm, a wall thickness of 9.5 mm, with a cross-sectional area of 70.4 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 503 cm³, and the elastic modulus Wel,y is 422 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 179 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,288 cm⁴, and about the minor axis Iz is 4,288 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.8 cm about the major axis and iz is 7.8 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.8 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 7,088 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 200×200×12SHS 200×200×12.5SHS 203×203×4.5SHS 203×203×6.4SHS 203×203×12.7SHS 250×250×6SHS 250×250×6.3SHS 250×250×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…