SHS 300×300×12.5 - Section Properties

The SHS 300×300×12.5 is a steel section with a mass of 108 kg/m, an overall depth of 300 mm and width of 300 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 137 cm², a second moment of area Iᵧ of 18350 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1451 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
108 kg/m
Depth
300 mm
Width
300 mm
Wall thickness
12.5 mm
Area
137 cm²
Ask about capacity, buckling or detailing for SHS 300×300×12.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 300×300×12.5

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 300×300×12.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh300
Width of sectionb300
Wall thicknesst12.5

Mass and area

Mass per metremass108
Cross-sectional areaA137

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy18350
Elastic section modulus about y-axisWel,y1223
Plastic section modulus about y-axisWpl,y1451
Radius of gyration about y-axisiy11.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz18350
Elastic section modulus about z-axisWel,z1223
Plastic section modulus about z-axisWpl,z1451
Radius of gyration about z-axisiz11.6

Torsion and warping

Torsion constant (St Venant)It30600
Section modulus for torsionWt1892

Surface area

Surface area per metreSA/m1.14

Is SHS 300×300×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
155.3 / 515.1 kNm
Shear7%
103.5 / 1404.0 kN
Deflection60%
10.1 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 300×300×12.5

SHS 300×300×12.5 has a mass of 108 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1296 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 300×300×12.5 has a depth of 300 mm, a width of 300 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 137 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,451 cm³, and the elastic modulus Wel,y is 1,223 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 515 kNm before any stability check.

The second moment of area about the major axis, Iy, is 18,350 cm⁴, and about the minor axis Iz is 18,350 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.6 cm about the major axis and iz is 11.6 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 11.6 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 30,600 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 300×300×8SHS 300×300×9SHS 300×300×10SHS 300×300×12SHS 300×300×16SHS 350×350×9SHS 350×350×12SHS 350×350×16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…