CivilAxisCivilAxis
☕ Support🌐 Community

SHS 350×350×12 - Section Properties

The SHS 350×350×12 is a steel section with a mass of 124 kg/m, an overall depth of 350 mm and width of 350 mm and a wall thickness of 12 mm. It has a cross-sectional area of 156 cm², a second moment of area Iᵧ of 29050 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1949 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
124 kg/m
Depth
350 mm
Width
350 mm
Wall thickness
12 mm
Area
156 cm²
Ask about capacity, buckling or detailing for SHS 350×350×12.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for SHS 350×350×12

Dimension symbols for SHS Cold-formed sections. Not to scale.

SHS 350×350×12 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh350
Width of sectionb350
Wall thicknesst12

Mass and area

Mass per metremass124
Cross-sectional areaA156

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy29050
Elastic section modulus about y-axisWel,y1660
Plastic section modulus about y-axisWpl,y1949
Radius of gyration about y-axisiy13.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz29050
Elastic section modulus about z-axisWel,z1660
Plastic section modulus about z-axisWpl,z1949
Radius of gyration about z-axisiz13.6

Torsion and warping

Torsion constant (St Venant)It47600
Section modulus for torsionWt2552

Surface area

Surface area per metreSA/m1.34

Is SHS 350×350×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
211.3 / 691.9 kNm
Shear8%
120.8 / 1598.7 kN
Deflection61%
11.8 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 350×350×12

SHS 350×350×12 has a mass of 124 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1488 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 350×350×12 has a depth of 350 mm, a width of 350 mm, a wall thickness of 12 mm, with a cross-sectional area of 156 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,949 cm³, and the elastic modulus Wel,y is 1,660 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 692 kNm before any stability check.

The second moment of area about the major axis, Iy, is 29,050 cm⁴, and about the minor axis Iz is 29,050 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 13.6 cm about the major axis and iz is 13.6 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 13.6 cm a 1.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 47,600 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

SHS 300×300×12SHS 300×300×12.5SHS 300×300×16SHS 350×350×9SHS 350×350×16SHS 400×400×9SHS 400×400×12SHS 400×400×16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…