SHS 160×160×16 - Section Properties
The SHS 160×160×16 is a steel section with a mass of 70.2 kg/m, an overall depth of 160 mm and width of 160 mm and a wall thickness of 16 mm. It has a cross-sectional area of 89.4 cm², a second moment of area Iᵧ of 3028 cm⁴, a plastic modulus Wₚₗ,ᵧ of 476 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 160×160×16.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 160×160×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
50.6 / 169.0 kNmShear7%
67.5 / 916.2 kNDeflection60%
5.0 / 8.3 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 160×160×16
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…