SHS 180×180×10 - Section Properties
The SHS 180×180×10 is a steel section with a mass of 53 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 10 mm. It has a cross-sectional area of 66.9 cm², a second moment of area Iᵧ of 3193 cm⁴, a plastic modulus Wₚₗ,ᵧ of 424 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 180×180×10.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 180×180×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending31%
45.9 / 150.5 kNmShear8%
52.5 / 685.6 kNDeflection60%
5.8 / 9.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 180×180×10
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…