SHS 180×180×16 - Section Properties
The SHS 180×180×16 is a steel section with a mass of 81.4 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 16 mm. It has a cross-sectional area of 102 cm², a second moment of area Iᵧ of 4504 cm⁴, a plastic modulus Wₚₗ,ᵧ of 621 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 180×180×16.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 180×180×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending29%
64.3 / 220.5 kNmShear7%
73.5 / 1045.3 kNDeflection59%
5.8 / 9.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 180×180×16
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…