CivilAxisCivilAxis
☕ Support🌐 Community

SHS 200×200×12.5 - Section Properties

The SHS 200×200×12.5 is a steel section with a mass of 73 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 92.1 cm², a second moment of area Iᵧ of 5336 cm⁴, a plastic modulus Wₚₗ,ᵧ of 643 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
73 kg/m
Depth
200 mm
Width
200 mm
Wall thickness
12.5 mm
Area
92.1 cm²
Ask about capacity, buckling or detailing for SHS 200×200×12.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS section profile showing the dimension symbols used for SHS 200×200×12.5

Dimension symbols for SHS sections. Not to scale.

SHS 200×200×12.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh200
Width of sectionb200
Wall thicknesst12.5

Mass and area

Mass per metremass73
Cross-sectional areaA92.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5336
Elastic section modulus about y-axisWel,y534
Plastic section modulus about y-axisWpl,y643
Radius of gyration about y-axisiy7.61

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz5336
Elastic section modulus about z-axisWel,z534
Plastic section modulus about z-axisWpl,z643
Radius of gyration about z-axisiz7.61

Torsion and warping

Torsion constant (St Venant)It8491
Section modulus for torsionWt778

Surface area

Surface area per metreSA/m0.768

Is SHS 200×200×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending29%
66.0 / 228.3 kNm
Shear7%
66.0 / 943.8 kN
Deflection59%
6.5 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 200×200×12.5

SHS 200×200×12.5 has a mass of 73 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 876 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 200×200×12.5 has a depth of 200 mm, a width of 200 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 92.1 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 643 cm³, and the elastic modulus Wel,y is 534 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 228 kNm before any stability check.

The second moment of area about the major axis, Iy, is 5,336 cm⁴, and about the minor axis Iz is 5,336 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.61 cm about the major axis and iz is 7.61 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.61 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 8,491 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS sizes

SHS 200×200×6SHS 200×200×6.3SHS 200×200×8SHS 200×200×10SHS 200×200×16SHS 220×220×5SHS 220×220×6SHS 220×220×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS sizes
Square Hollow Sections (SHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…