SHS 200×200×16 - Section Properties
The SHS 200×200×16 is a steel section with a mass of 91.5 kg/m, an overall depth of 200 mm and width of 200 mm and a wall thickness of 16 mm. It has a cross-sectional area of 115 cm², a second moment of area Iᵧ of 6394 cm⁴, a plastic modulus Wₚₗ,ᵧ of 785 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 200×200×16.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 200×200×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending29%
81.0 / 278.7 kNmShear7%
81.0 / 1178.5 kNDeflection60%
6.7 / 11.1 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 200×200×16
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…