CivilAxisCivilAxis
☕ Support🌐 Community

SHS 260×260×12.5 - Section Properties

The SHS 260×260×12.5 is a steel section with a mass of 95.8 kg/m, an overall depth of 260 mm and width of 260 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 122 cm², a second moment of area Iᵧ of 12370 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1127 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
95.8 kg/m
Depth
260 mm
Width
260 mm
Wall thickness
12.5 mm
Area
122 cm²
Ask about capacity, buckling or detailing for SHS 260×260×12.5.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS section profile showing the dimension symbols used for SHS 260×260×12.5

Dimension symbols for SHS sections. Not to scale.

SHS 260×260×12.5 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh260
Width of sectionb260
Wall thicknesst12.5

Mass and area

Mass per metremass95.8
Cross-sectional areaA122

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy12370
Elastic section modulus about y-axisWel,y951
Plastic section modulus about y-axisWpl,y1127
Radius of gyration about y-axisiy10.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz12370
Elastic section modulus about z-axisWel,z951
Plastic section modulus about z-axisWpl,z1127
Radius of gyration about z-axisiz10.1

Torsion and warping

Torsion constant (St Venant)It19410
Section modulus for torsionWt1394

Surface area

Surface area per metreSA/m1.01

Is SHS 260×260×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
126.6 / 400.1 kNm
Shear8%
101.3 / 1250.3 kN
Deflection61%
8.5 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 260×260×12.5

SHS 260×260×12.5 has a mass of 95.8 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1150 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 260×260×12.5 has a depth of 260 mm, a width of 260 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 122 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,127 cm³, and the elastic modulus Wel,y is 951 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 400 kNm before any stability check.

The second moment of area about the major axis, Iy, is 12,370 cm⁴, and about the minor axis Iz is 12,370 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 10.1 cm about the major axis and iz is 10.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.1 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 19,410 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS sizes

SHS 260×260×6.3SHS 260×260×8SHS 260×260×10SHS 260×260×12SHS 260×260×14SHS 260×260×14.2SHS 260×260×16SHS 300×300×6.3

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 250×250×14.2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS sizes
Square Hollow Sections (SHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…