CivilAxisCivilAxis
☕ Support🌐 Community

SHS 400×400×12 - Section Properties

The SHS 400×400×12 is a steel section with a mass of 145 kg/m, an overall depth of 400 mm and width of 400 mm and a wall thickness of 12 mm. It has a cross-sectional area of 185 cm², a second moment of area Iᵧ of 46130 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2679 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
145 kg/m
Depth
400 mm
Width
400 mm
Wall thickness
12 mm
Area
185 cm²
Ask about capacity, buckling or detailing for SHS 400×400×12.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS section profile showing the dimension symbols used for SHS 400×400×12

Dimension symbols for SHS sections. Not to scale.

SHS 400×400×12 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh400
Width of sectionb400
Wall thicknesst12

Mass and area

Mass per metremass145
Cross-sectional areaA185

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy46130
Elastic section modulus about y-axisWel,y2306
Plastic section modulus about y-axisWpl,y2679
Radius of gyration about y-axisiy15.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz46130
Elastic section modulus about z-axisWel,z2306
Plastic section modulus about z-axisWpl,z2679
Radius of gyration about z-axisiz15.8

Torsion and warping

Torsion constant (St Venant)It71180
Section modulus for torsionWt3405

Surface area

Surface area per metreSA/m1.57

Is SHS 400×400×12 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
288.0 / 951.0 kNm
Shear8%
144.0 / 1895.9 kN
Deflection59%
13.2 / 22.2 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 400×400×12

SHS 400×400×12 has a mass of 145 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 1740 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 400×400×12 has a depth of 400 mm, a width of 400 mm, a wall thickness of 12 mm, with a cross-sectional area of 185 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,679 cm³, and the elastic modulus Wel,y is 2,306 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 951 kNm before any stability check.

The second moment of area about the major axis, Iy, is 46,130 cm⁴, and about the minor axis Iz is 46,130 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 15.8 cm about the major axis and iz is 15.8 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 15.8 cm a 1.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 71,180 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS sizes

SHS 350×350×22SHS 350×350×25SHS 400×400×8SHS 400×400×10SHS 400×400×12.5SHS 400×400×14SHS 400×400×14.2SHS 400×400×16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS sizes
Square Hollow Sections (SHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…