SHS 400×400×16 - Section Properties
The SHS 400×400×16 is a steel section with a mass of 192 kg/m, an overall depth of 400 mm and width of 400 mm and a wall thickness of 16 mm. It has a cross-sectional area of 243 cm², a second moment of area Iᵧ of 59340 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3484 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 400×400×16.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 400×400×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
372.0 / 1236.8 kNmShear7%
186.0 / 2490.3 kNDeflection60%
13.3 / 22.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.