SHS 500×500×16 - Section Properties
The SHS 500×500×16 is a steel section with a mass of 238 kg/m, an overall depth of 500 mm and width of 500 mm and a wall thickness of 16 mm. It has a cross-sectional area of 307 cm², a second moment of area Iᵧ of 119300 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5554 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 500×500×16.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 500×500×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
600.0 / 1971.7 kNmShear8%
240.0 / 3146.1 kNDeflection60%
16.6 / 27.8 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 500×500×16
Related SHS sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…