SHS 500×500×25 - Section Properties
The SHS 500×500×25 is a steel section with a mass of 360 kg/m, an overall depth of 500 mm and width of 500 mm and a wall thickness of 25 mm. It has a cross-sectional area of 468 cm², a second moment of area Iᵧ of 174600 cm⁴, a plastic modulus Wₚₗ,ᵧ of 8295 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 500×500×25.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 500×500×25 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending31%
881.3 / 2861.8 kNmShear8%
352.5 / 4660.9 kNDeflection60%
16.7 / 27.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.