SHS 75×75×8 - Section Properties
The SHS 75×75×8 is a steel section with a mass of 16.6 kg/m, an overall depth of 75 mm and width of 75 mm and a wall thickness of 8 mm. It has a cross-sectional area of 20.8 cm², a second moment of area Iᵧ of 152 cm⁴, a plastic modulus Wₚₗ,ᵧ of 51.3 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.
Ask about capacity, buckling or detailing for SHS 75×75×8.
or pick a unit on any row

Dimension symbols for SHS sections. Not to scale.
Is SHS 75×75×8 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending28%
5.1 / 18.2 kNmShear6%
13.5 / 213.2 kNDeflection59%
2.5 / 4.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.