CivilAxisCivilAxis
☕ Support🌐 Community

SHS 80×80×3.6 - Section Properties

The SHS 80×80×3.6 is a steel section with a mass of 8.59 kg/m, an overall depth of 80 mm and width of 80 mm and a wall thickness of 3.6 mm. It has a cross-sectional area of 10.9 cm², a second moment of area Iᵧ of 105 cm⁴, a plastic modulus Wₚₗ,ᵧ of 31 cm³, tabulated by CivilAxis from EN 10219 · Continental Steel.

Mass
8.59 kg/m
Depth
80 mm
Width
80 mm
Wall thickness
3.6 mm
Area
10.9 cm²
Ask about capacity, buckling or detailing for SHS 80×80×3.6.
🔍 Open the full Steel Catalogue
or pick a unit on any row
SHS section profile showing the dimension symbols used for SHS 80×80×3.6

Dimension symbols for SHS sections. Not to scale.

SHS 80×80×3.6 section properties to EN 10219 · Continental Steel.

Geometry

Depth of sectionh80
Width of sectionb80
Wall thicknesst3.6

Mass and area

Mass per metremass8.59
Cross-sectional areaA10.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy105
Elastic section modulus about y-axisWel,y26.2
Plastic section modulus about y-axisWpl,y31
Radius of gyration about y-axisiy3.11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz105
Elastic section modulus about z-axisWel,z26.2
Plastic section modulus about z-axisWpl,z31
Radius of gyration about z-axisiz3.11

Torsion and warping

Torsion constant (St Venant)It164
Section modulus for torsionWt38.5

Surface area

Surface area per metreSA/m0.311

Is SHS 80×80×3.6 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
3.6 / 11.0 kNm
Shear9%
9.6 / 111.7 kN
Deflection61%
2.5 / 4.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 80×80×3.6

SHS 80×80×3.6 has a mass of 8.59 kg/m, tabulated to EN 10219. A 12 m length therefore weighs about 103 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 80×80×3.6 has a depth of 80 mm, a width of 80 mm, a wall thickness of 3.6 mm, with a cross-sectional area of 10.9 cm². These are the nominal dimensions from EN 10219; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 31 cm³, and the elastic modulus Wel,y is 26.2 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 11 kNm before any stability check.

The second moment of area about the major axis, Iy, is 105 cm⁴, and about the minor axis Iz is 105 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 3.11 cm about the major axis and iz is 3.11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.11 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 164 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS sizes

SHS 75×75×6SHS 75×75×6.3SHS 75×75×8SHS 80×80×3SHS 80×80×5SHS 80×80×6SHS 80×80×6.3SHS 80×80×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS sizes
Square Hollow Sections (SHS)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…