EHS 400×200×10 - Section Properties
The EHS 400×200×10 is a elliptical hollow section with a mass of 71.5 kg/m, an overall depth of 400 mm and width of 200 mm and a wall thickness of 10 mm. It has a cross-sectional area of 91.1 cm², a second moment of area Iᵧ of 14300 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1000 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for EHS 400×200×10.
or pick a unit on any row

Dimension symbols for EHS Hot-finished sections. Not to scale.
Is EHS 400×200×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending25%
90.0 / 355.0 kNmShear4%
45.0 / 1244.8 kNDeflection60%
13.3 / 22.2 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about EHS 400×200×10
Related EHS Hot-finished sizes
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.
Loading…