CivilAxisCivilAxis
☕ Support🌐 Community

FB 12×200 - Section Properties

The FB 12×200 is a steel section with a mass of 18.84 kg/m, an overall depth of 200 mm and width of 12 mm and a wall thickness of 12 mm. It has a cross-sectional area of 24 cm², a second moment of area Iᵧ of 800 cm⁴, a plastic modulus Wₚₗ,ᵧ of 120 cm³, tabulated by CivilAxis from EN 10058 · Continental Steel.

Mass
18.84 kg/m
Depth
200 mm
Width
12 mm
Wall thickness
12 mm
Area
24 cm²
Ask about capacity, buckling or detailing for FB 12×200.
🔍 Open the full Steel Catalogue
or pick a unit on any row
FB 12×200 section properties to EN 10058 · Continental Steel.

Geometry

Depth of sectionh200
Width of sectionb12
Wall thicknesst12

Mass and area

Mass per metremass18.84
Cross-sectional areaA24

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy800
Elastic section modulus about y-axisWel,y80
Plastic section modulus about y-axisWpl,y120
Radius of gyration about y-axisiy5.77

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2.88
Elastic section modulus about z-axisWel,z4.8
Plastic section modulus about z-axisWpl,z7.2
Radius of gyration about z-axisiz0.346

Common questions about FB 12×200

FB 12×200 has a mass of 18.84 kg/m, tabulated to EN 10058. A 12 m length therefore weighs about 226 kg, which is the figure to use for a steel take-off or when checking a lift.

FB 12×200 has a depth of 200 mm, a width of 12 mm, a wall thickness of 12 mm, with a cross-sectional area of 24 cm². These are the nominal dimensions from EN 10058; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 120 cm³, and the elastic modulus Wel,y is 80 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 43 kNm before any stability check.

The second moment of area about the major axis, Iy, is 800 cm⁴, and about the minor axis Iz is 2.88 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5.77 cm about the major axis and iz is 0.346 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 0.346 cm a 0.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Flat Bar sizes

FB 12×100FB 12×125FB 12×150FB 12×180FB 12×250FB 12×300FB 16×25FB 16×32

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)