FB 16×50 - Section Properties

The FB 16×50 is a steel section with a mass of 6.28 kg/m, an overall depth of 50 mm and width of 16 mm and a wall thickness of 16 mm. It has a cross-sectional area of 8 cm², a second moment of area Iᵧ of 16.67 cm⁴, a plastic modulus Wₚₗ,ᵧ of 10 cm³, tabulated by CivilAxis from EN 10058 · Continental Steel.

Mass
6.28 kg/m
Depth
50 mm
Width
16 mm
Wall thickness
16 mm
Area
8 cm²
Ask about capacity, buckling or detailing for FB 16×50.
🔍 Open the full Steel Catalogue
or pick a unit on any row
FB 16×50 section properties to EN 10058 · Continental Steel.

Geometry

Depth of sectionh50
Width of sectionb16
Wall thicknesst16

Mass and area

Mass per metremass6.28
Cross-sectional areaA8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy16.67
Elastic section modulus about y-axisWel,y6.667
Plastic section modulus about y-axisWpl,y10
Radius of gyration about y-axisiy1.44

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1.707
Elastic section modulus about z-axisWel,z2.133
Plastic section modulus about z-axisWpl,z3.2
Radius of gyration about z-axisiz0.462

Common questions about FB 16×50

FB 16×50 has a mass of 6.28 kg/m, tabulated to EN 10058. A 12 m length therefore weighs about 75 kg, which is the figure to use for a steel take-off or when checking a lift.

FB 16×50 has a depth of 50 mm, a width of 16 mm, a wall thickness of 16 mm, with a cross-sectional area of 8 cm². These are the nominal dimensions from EN 10058; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 10 cm³, and the elastic modulus Wel,y is 6.667 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 4 kNm before any stability check.

The second moment of area about the major axis, Iy, is 16.67 cm⁴, and about the minor axis Iz is 1.707 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 1.44 cm about the major axis and iz is 0.462 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 0.462 cm a 0.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Flat Bar sizes

FB 12×300FB 16×25FB 16×32FB 16×38FB 16×65FB 16×75FB 16×90FB 16×100

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Flat Bar sizes
Flat Bars
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…