CivilAxisCivilAxis
☕ Support🌐 Community

HE 200 AA - Section Properties

The HE 200 AA is a European wide-flange beam (HE) with a mass of 34.6 kg/m, an overall depth of 186 mm and width of 200 mm. It has a cross-sectional area of 44.1 cm², a second moment of area Iᵧ of 2940 cm⁴, a plastic modulus Wₚₗ,ᵧ of 347 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
34.6 kg/m
Depth
186 mm
Width
200 mm
Area
44.1 cm²
Ask about capacity, buckling or detailing for HE 200 AA.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 200 AA

Dimension symbols for HE sections. Not to scale.

HE 200 AA section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh186
Width of sectionb200
Web thicknesstw5.5
Flange thicknesstf8
Root fillet radiusr18
Depth between filletsd134

Mass and area

Mass per metremass34.6
Cross-sectional areaA44.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2940
Elastic section modulus about y-axisWel,y317
Plastic section modulus about y-axisWpl,y347
Radius of gyration about y-axisiy8.17

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1070
Elastic section modulus about z-axisWel,z107
Plastic section modulus about z-axisWpl,z163
Radius of gyration about z-axisiz4.92

Torsion and warping

Torsion constant (St Venant)It12.5
Warping constantIw0.0845

Classification and stability

Flange local-buckling ratiocf/tf9.91
Web local-buckling ratiocw/tw24.4
Buckling parameteru6.152
Torsional indexX18.9

Detailing dimensions

End clearanceC5
Notch dimension NN108
Notch dimension nn26

Surface area

Surface area per metreSA/m1.13

Is HE 200 AA strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending37%
41.3 / 112.5 kNm
Shear15%
47.3 / 316.0 kN
Deflection59%
5.7 / 9.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 200 AA

HE 200 AA has a mass of 34.6 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 415 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 200 AA has a depth of 186 mm, a width of 200 mm, a web thickness of 5.5 mm, a flange thickness of 8 mm, with a cross-sectional area of 44.1 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 347 cm³, and the elastic modulus Wel,y is 317 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 123 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,940 cm⁴, and about the minor axis Iz is 1,070 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 9.91 for the flange and cw/tw = 24.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.17 cm about the major axis and iz is 4.92 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.92 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 12.5 cm⁴, and the warping constant Iw is 0.0845 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 180 AHE 180 BHE 180 CHE 180 MHE 200 AHE 200 BHE 200 CHE 200 M

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.