The HE 700 A is a European wide-flange beam (HE) with a mass of 204 kg/m, an overall depth of 690 mm and width of 300 mm. It has a cross-sectional area of 260 cm², a second moment of area Iᵧ of 215000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 7030 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
204 kg/m
Depth
690 mm
Width
300 mm
Area
260 cm²
Ask about capacity, buckling or detailing for HE 700 A.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 700 A

Dimension symbols for HE sections. Not to scale.

HE 700 A section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh690
Width of sectionb300
Web thicknesstw14.5
Flange thicknesstf27
Root fillet radiusr27
Depth between filletsd582

Mass and area

Mass per metremass204
Cross-sectional areaA260

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy215000
Elastic section modulus about y-axisWel,y6240
Plastic section modulus about y-axisWpl,y7030
Radius of gyration about y-axisiy28.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz12200
Elastic section modulus about z-axisWel,z812
Plastic section modulus about z-axisWpl,z1260
Radius of gyration about z-axisiz6.84

Torsion and warping

Torsion constant (St Venant)It522
Warping constantIw13.4

Classification and stability

Flange local-buckling ratiocf/tf4.29
Web local-buckling ratiocw/tw40.1
Buckling parameteru7.897
Torsional indexX26.5

Detailing dimensions

End clearanceC9
Notch dimension NN154
Notch dimension nn54

Surface area

Surface area per metreSA/m2.5

Is HE 700 A strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending36%
891.0 / 2495.7 kNm
Shear12%
297.0 / 2387.7 kN
Deflection59%
19.7 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 700 A

HE 700 A has a mass of 204 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 2448 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 700 A has a depth of 690 mm, a width of 300 mm, a web thickness of 14.5 mm, a flange thickness of 27 mm, with a cross-sectional area of 260 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 7,030 cm³, and the elastic modulus Wel,y is 6,240 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2496 kNm before any stability check.

The second moment of area about the major axis, Iy, is 215,000 cm⁴, and about the minor axis Iz is 12,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.29 for the flange and cw/tw = 40.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 28.8 cm about the major axis and iz is 6.84 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.84 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 522 cm⁴, and the warping constant Iw is 13.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 650 MHE 650 x 343HE 650 x 407HE 700 AAHE 700 BHE 700 MHE 700 x 352HE 700 x 418

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…