CivilAxisCivilAxis
☕ Support🌐 Community

HE 800 AA - Section Properties

The HE 800 AA is a European wide-flange beam (HE) with a mass of 172 kg/m, an overall depth of 770 mm and width of 300 mm. It has a cross-sectional area of 218 cm², a second moment of area Iᵧ of 209000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 6220 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
172 kg/m
Depth
770 mm
Width
300 mm
Area
218 cm²
Ask about capacity, buckling or detailing for HE 800 AA.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
HE section profile showing the dimension symbols used for HE 800 AA

Dimension symbols for HE sections. Not to scale.

HE 800 AA section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh770
Width of sectionb300
Web thicknesstw14
Flange thicknesstf18
Root fillet radiusr30
Depth between filletsd674

Mass and area

Mass per metremass172
Cross-sectional areaA218

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy209000
Elastic section modulus about y-axisWel,y5430
Plastic section modulus about y-axisWpl,y6220
Radius of gyration about y-axisiy30.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz8130
Elastic section modulus about z-axisWel,z542
Plastic section modulus about z-axisWpl,z857
Radius of gyration about z-axisiz6.1

Torsion and warping

Torsion constant (St Venant)It243
Warping constantIw11.4

Classification and stability

Flange local-buckling ratiocf/tf6.28
Web local-buckling ratiocw/tw48.1
Buckling parameteru7.424
Torsional indexX40.2

Detailing dimensions

End clearanceC9
Notch dimension NN154
Notch dimension nn48

Surface area

Surface area per metreSA/m2.66

Is HE 800 AA strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending40%
891.0 / 2208.1 kNm
Shear12%
297.0 / 2527.6 kN
Deflection61%
20.3 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HE 800 AA

HE 800 AA has a mass of 172 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 2064 kg, which is the figure to use for a steel take-off or when checking a lift.

HE 800 AA has a depth of 770 mm, a width of 300 mm, a web thickness of 14 mm, a flange thickness of 18 mm, with a cross-sectional area of 218 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 6,220 cm³, and the elastic modulus Wel,y is 5,430 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2208 kNm before any stability check.

The second moment of area about the major axis, Iy, is 209,000 cm⁴, and about the minor axis Iz is 8,130 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.28 for the flange and cw/tw = 48.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 30.9 cm about the major axis and iz is 6.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.1 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 243 cm⁴, and the warping constant Iw is 11.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HE sizes

HE 700 BHE 700 MHE 700 x 352HE 700 x 418HE 800 AHE 800 BHE 800 MHE 800 x 373

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 762×267×173vs W 30X116

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HE sizes
Wide-Flange Beams (HEA/HEB/HEM)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…