CivilAxisCivilAxis
☕ Support🌐 Community

IPE 450 - Section Properties

The IPE 450 is a European I-beam (IPE) with a mass of 77.6 kg/m, an overall depth of 450 mm and width of 190 mm. It has a cross-sectional area of 98.8 cm², a second moment of area Iᵧ of 33700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1700 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
77.6 kg/m
Depth
450 mm
Width
190 mm
Area
98.8 cm²
Ask about capacity, buckling or detailing for IPE 450.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE 450

Dimension symbols for IPE sections. Not to scale.

IPE 450 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh450
Width of sectionb190
Web thicknesstw9.4
Flange thicknesstf14.6
Root fillet radiusr21
Depth between filletsd378.8

Mass and area

Mass per metremass77.6
Cross-sectional areaA98.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy33700
Elastic section modulus about y-axisWel,y1500
Plastic section modulus about y-axisWpl,y1700
Radius of gyration about y-axisiy18.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1680
Elastic section modulus about z-axisWel,z176
Plastic section modulus about z-axisWpl,z276
Radius of gyration about z-axisiz4.12

Torsion and warping

Torsion constant (St Venant)It66.7
Warping constantIw0.791

Classification and stability

Flange local-buckling ratiocf/tf4.75
Web local-buckling ratiocw/tw40.3
Buckling parameteru6.118
Torsional indexX29.9

Detailing dimensions

End clearanceC7
Notch dimension NN102
Notch dimension nn36

Surface area

Surface area per metreSA/m1.61

Is IPE 450 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending30%
182.3 / 603.5 kNm
Shear8%
81.0 / 1041.7 kN
Deflection58%
14.5 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE 450

IPE 450 has a mass of 77.6 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 931 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE 450 has a depth of 450 mm, a width of 190 mm, a web thickness of 9.4 mm, a flange thickness of 14.6 mm, with a cross-sectional area of 98.8 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,700 cm³, and the elastic modulus Wel,y is 1,500 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 604 kNm before any stability check.

The second moment of area about the major axis, Iy, is 33,700 cm⁴, and about the minor axis Iz is 1,680 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.75 for the flange and cw/tw = 40.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.5 cm about the major axis and iz is 4.12 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.12 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 66.7 cm⁴, and the warping constant Iw is 0.791 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE 400IPE O 400IPE V 400IPE A 450IPE O 450IPE V 450IPE A 500IPE 500

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 457×191×74vs W 18X50vs S 18X54.7vs H-450x200x9x14-76vs UB 457×152×74

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…