CivilAxisCivilAxis
☕ Support🌐 Community

IPE A 120 - Section Properties

The IPE A 120 is a European I-beam (IPE) with a mass of 8.7 kg/m, an overall depth of 117.6 mm and width of 64 mm. It has a cross-sectional area of 11 cm², a second moment of area Iᵧ of 257 cm⁴, a plastic modulus Wₚₗ,ᵧ of 49.9 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
8.7 kg/m
Depth
117.6 mm
Width
64 mm
Area
11 cm²
Ask about capacity, buckling or detailing for IPE A 120.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE A 120

Dimension symbols for IPE sections. Not to scale.

IPE A 120 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh117.6
Width of sectionb64
Web thicknesstw3.8
Flange thicknesstf5.1
Root fillet radiusr7
Depth between filletsd93.4

Mass and area

Mass per metremass8.7
Cross-sectional areaA11

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy257
Elastic section modulus about y-axisWel,y43.8
Plastic section modulus about y-axisWpl,y49.9
Radius of gyration about y-axisiy4.83

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz22.4
Elastic section modulus about z-axisWel,z7
Plastic section modulus about z-axisWpl,z11
Radius of gyration about z-axisiz1.42

Torsion and warping

Torsion constant (St Venant)It1
Warping constantIw0.00071

Classification and stability

Flange local-buckling ratiocf/tf4.53
Web local-buckling ratiocw/tw24.6
Buckling parameteru3.577
Torsional indexX21.2

Detailing dimensions

End clearanceC4
Notch dimension NN42
Notch dimension nn14

Surface area

Surface area per metreSA/m0.472

Is IPE A 120 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending30%
5.3 / 17.7 kNm
Shear8%
8.4 / 110.3 kN
Deflection61%
4.2 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE A 120

IPE A 120 has a mass of 8.7 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 104 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE A 120 has a depth of 117.6 mm, a width of 64 mm, a web thickness of 3.8 mm, a flange thickness of 5.1 mm, with a cross-sectional area of 11 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 49.9 cm³, and the elastic modulus Wel,y is 43.8 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 18 kNm before any stability check.

The second moment of area about the major axis, Iy, is 257 cm⁴, and about the minor axis Iz is 22.4 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.53 for the flange and cw/tw = 24.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 4.83 cm about the major axis and iz is 1.42 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.42 cm a 0.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1 cm⁴, and the warping constant Iw is 0.00071 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE AA 100IPE A 100IPE 100IPE AA 120IPE 120IPE AA 140IPE A 140IPE 140

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…