CivilAxisCivilAxis
☕ Support🌐 Community

IPE AA 200 - Section Properties

The IPE AA 200 is a European I-beam (IPE) with a mass of 18 kg/m, an overall depth of 196.4 mm and width of 100 mm. It has a cross-sectional area of 22.9 cm², a second moment of area Iᵧ of 1530 cm⁴, a plastic modulus Wₚₗ,ᵧ of 176 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
18 kg/m
Depth
196.4 mm
Width
100 mm
Area
22.9 cm²
Ask about capacity, buckling or detailing for IPE AA 200.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE AA 200

Dimension symbols for IPE sections. Not to scale.

IPE AA 200 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh196.4
Width of sectionb100
Web thicknesstw4.5
Flange thicknesstf6.7
Root fillet radiusr12
Depth between filletsd159

Mass and area

Mass per metremass18
Cross-sectional areaA22.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1530
Elastic section modulus about y-axisWel,y156
Plastic section modulus about y-axisWpl,y176
Radius of gyration about y-axisiy8.19

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz112
Elastic section modulus about z-axisWel,z22
Plastic section modulus about z-axisWpl,z35
Radius of gyration about z-axisiz2.21

Torsion and warping

Torsion constant (St Venant)It3.81
Warping constantIw0.0101

Classification and stability

Flange local-buckling ratiocf/tf5.34
Web local-buckling ratiocw/tw35.3
Buckling parameteru4.472
Torsional indexX26.3

Detailing dimensions

End clearanceC4
Notch dimension NN58
Notch dimension nn20

Surface area

Surface area per metreSA/m0.763

Is IPE AA 200 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
19.5 / 62.5 kNm
Shear8%
19.5 / 233.8 kN
Deflection61%
6.7 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE AA 200

IPE AA 200 has a mass of 18 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 216 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE AA 200 has a depth of 196.4 mm, a width of 100 mm, a web thickness of 4.5 mm, a flange thickness of 6.7 mm, with a cross-sectional area of 22.9 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 176 cm³, and the elastic modulus Wel,y is 156 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 62 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,530 cm⁴, and about the minor axis Iz is 112 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.34 for the flange and cw/tw = 35.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.19 cm about the major axis and iz is 2.21 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.21 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3.81 cm⁴, and the warping constant Iw is 0.0101 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE AA 180IPE A 180IPE 180IPE O 180IPE A 200IPE 200IPE O 200IPE AA 220

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…