CivilAxisCivilAxis
☕ Support🌐 Community

IPE O 200 - Section Properties

The IPE O 200 is a European I-beam (IPE) with a mass of 25.1 kg/m, an overall depth of 202 mm and width of 102 mm. It has a cross-sectional area of 32 cm², a second moment of area Iᵧ of 2210 cm⁴, a plastic modulus Wₚₗ,ᵧ of 249 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
25.1 kg/m
Depth
202 mm
Width
102 mm
Area
32 cm²
Ask about capacity, buckling or detailing for IPE O 200.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE O 200

Dimension symbols for IPE sections. Not to scale.

IPE O 200 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh202
Width of sectionb102
Web thicknesstw6.2
Flange thicknesstf9.5
Root fillet radiusr12
Depth between filletsd159

Mass and area

Mass per metremass25.1
Cross-sectional areaA32

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2210
Elastic section modulus about y-axisWel,y219
Plastic section modulus about y-axisWpl,y249
Radius of gyration about y-axisiy8.32

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz169
Elastic section modulus about z-axisWel,z33
Plastic section modulus about z-axisWpl,z51.9
Radius of gyration about z-axisiz2.3

Torsion and warping

Torsion constant (St Venant)It9.36
Warping constantIw0.0156

Classification and stability

Flange local-buckling ratiocf/tf3.78
Web local-buckling ratiocw/tw25.6
Buckling parameteru4.547
Torsional indexX20.1

Detailing dimensions

End clearanceC5
Notch dimension NN58
Notch dimension nn22

Surface area

Surface area per metreSA/m0.779

Is IPE O 200 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
28.5 / 88.4 kNm
Shear9%
28.5 / 317.5 kN
Deflection61%
6.8 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE O 200

IPE O 200 has a mass of 25.1 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 301 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE O 200 has a depth of 202 mm, a width of 102 mm, a web thickness of 6.2 mm, a flange thickness of 9.5 mm, with a cross-sectional area of 32 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 249 cm³, and the elastic modulus Wel,y is 219 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 88 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,210 cm⁴, and about the minor axis Iz is 169 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.78 for the flange and cw/tw = 25.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.32 cm about the major axis and iz is 2.3 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.3 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9.36 cm⁴, and the warping constant Iw is 0.0156 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE O 180IPE AA 200IPE A 200IPE 200IPE AA 220IPE A 220IPE 220IPE O 220

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 203×133×25

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…