CivilAxisCivilAxis
☕ Support🌐 Community

IPE A 220 - Section Properties

The IPE A 220 is a European I-beam (IPE) with a mass of 22.2 kg/m, an overall depth of 217 mm and width of 110 mm. It has a cross-sectional area of 28.3 cm², a second moment of area Iᵧ of 2320 cm⁴, a plastic modulus Wₚₗ,ᵧ of 240 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
22.2 kg/m
Depth
217 mm
Width
110 mm
Area
28.3 cm²
Ask about capacity, buckling or detailing for IPE A 220.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE A 220

Dimension symbols for IPE sections. Not to scale.

IPE A 220 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh217
Width of sectionb110
Web thicknesstw5
Flange thicknesstf7.7
Root fillet radiusr12
Depth between filletsd177.6

Mass and area

Mass per metremass22.2
Cross-sectional areaA28.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2320
Elastic section modulus about y-axisWel,y214
Plastic section modulus about y-axisWpl,y240
Radius of gyration about y-axisiy9.05

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz171
Elastic section modulus about z-axisWel,z31
Plastic section modulus about z-axisWpl,z48.5
Radius of gyration about z-axisiz2.46

Torsion and warping

Torsion constant (St Venant)It5.68
Warping constantIw0.0187

Classification and stability

Flange local-buckling ratiocf/tf5.26
Web local-buckling ratiocw/tw35.5
Buckling parameteru4.709
Torsional indexX26.4

Detailing dimensions

End clearanceC5
Notch dimension NN64
Notch dimension nn20

Surface area

Surface area per metreSA/m0.843

Is IPE A 220 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
26.6 / 85.2 kNm
Shear8%
23.6 / 278.6 kN
Deflection61%
7.7 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE A 220

IPE A 220 has a mass of 22.2 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 266 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE A 220 has a depth of 217 mm, a width of 110 mm, a web thickness of 5 mm, a flange thickness of 7.7 mm, with a cross-sectional area of 28.3 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 240 cm³, and the elastic modulus Wel,y is 214 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 85 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,320 cm⁴, and about the minor axis Iz is 171 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.26 for the flange and cw/tw = 35.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.05 cm about the major axis and iz is 2.46 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.46 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5.68 cm⁴, and the warping constant Iw is 0.0187 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE A 200IPE 200IPE O 200IPE AA 220IPE 220IPE O 220IPE AA 240IPE A 240

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…